Home page
 
 
Our company News Catalogue New products Order Contact us
Home page e-mail us Site map
SEC-Sensor for gas Carbon Monoxide CO.1000 ppm

SEC-Sensor for gas Carbon Monoxide CO.1000 ppm

Specification Sheet Carbon Monoxide

Sensor Type CO Carbon Monoxide
Part umber SECS CO 1000
Detectable Gases CO
Measuring Principle Amperometric 3-electrode sensor
Color of Sensor Cap White
Specific Sensor Data No
Connector 3pin
Standard Range 0 - 1000ppm
Lower Detectable Limit (LDL) 10 ppm
Maximum Range 2000ppm
MAK/TLV 30 ppm
LEL -
Sensor Decay < 1%/month
Deviation from Linearity at standard Range < 20%FS
Zero Current at normal conditions +- 100nA
 
Sensitivity 10nA to 100nA/ppm
 
Response Time at target Level
t50 < 30s
t90 < 100s
 
Sensor warm up time typically 20s
Operating conditions -20-+50C; 15-90%r.h. n-c
Temperature dependence <0.5%/C
Sensor life 5years expected
 
Sensor dimension (L x W x H) 10mm x 8mm x 1mm
 

 

Specification Sheet Carbon Monoxide

Cross Sensitivity

Gas
TestGas Gas
Concentration
Readinginppm
Ammonia
NH3
25ppm
0.0
Carbon Dioxide
CO2
5000ppm
0.0
Carbon Monoxide
CO
60ppm
60
Chlorine
Cl2
1.0ppm
?
Hydrocarbons
unsaturated
1%
0.0
Hydrogen
H2
100ppm
90
Hydrogen Sulphide
H2S
1ppm
40
Isopropanol
C3H7OH
1000ppm
?
Nitric Oxide
NO
20ppm
?
Nitrogen Dioxide
NO2
10ppm
?
Ozone
O3
0.5ppm
?
Sulphur Dioxide
SO2
20ppm
?
 

 

PLEASE NOTE

Test Conditions at 20C, P at 1013hPa, Flow Rate > 500qcm/min Cross sensitivity gases are not target gases. Relation can change with aging.

(1) Value is below the recommended Lower Detectable Limit

Download Pricelist 2009.pdf

 

top

 

Homepage  

Copyright 2003-2011 MST IT
Powered by ProfSolutions.ru
Supported by Prof-Support.ru